Safevolt™ EV PME automatic fault detector

Safevolt™ EV PME automatic fault detector

Safevolt™ EV PME automatic fault detector

Back to Range

The New Safevolt™ - Install charge points compliant with 18th Edition recommendations and IET Code of Practice for Electric Vehicle Charging Equipment

Shop Online

Click on the product categories to buy online!

Free Delivery

Free Delivery*
*available on selected products only

.

Simple indoor installation of the SafeVolt™ PEN fault detector 

No need to convert to TT or install isolation transformer or earth electrodes - eliminate site excavation and making good with the simple installation of the SafeVolt™ unit indoors - section 722.411.4.1 (iii)) protection against shock may be provided by a device which disconnects the EVSE from the line, neutral and PE of the supply within 5 seconds in the event of the voltage between the PME and true earth exceeds 70 V rms, - CityEV Safe-volt™ install the micro ground connection and simply connect in series with the charge point - disconnects L/N/E in the event of a PEN fault - clear indication and manual reset by consumer. Works with any single phase EV charge point up to 7Kw, 32A

Works with any charge point up to 32A
Simple installation - 3 year warranty
 
 
 

No need for isolation transformer or convert to TT -utilise existing PME 

No excavation for earth electrodes - maintains touch safe distance 

Fail safe automatic operation safe and reliable, manual reset

Use on single phase PME installations & unbalanced phase installs - micro earth sensor 

British designed and manufactured - IET Code compliant

 

 

 

 

OPERATING PARAMETERS

 

Operating Voltage Range (AC)                                       205V to 260V     

Maximum Load Current                                                  35A

Earth Fault Isolation                                                        3 pole - L, N, E

Maximum Sense Probe Earth Loop Impendence          120K Ohm

Earth Fault Touch Voltage Trip Threshold                      70VAC

Earth Fault Trip Delay                                                    4 Seconds

Earth Fault Trip Reset                                                    Manual

Connectors                                                                    Terminals L/N/E  min 2.5mm2 - max 6mm2

 

INDICATORS

Mains Power On

Output On

Sense Probe Fault

Earth Fault Trip

 

CONTROLS

Test

Earth Fault Trip Reset

 

DIAGNOSTICS

Continuous monitoring of sense probe impendence with fault indication and output isolation in case of fault

 

DIMENSIONS

210mm W x 140mm H x 75mm D

Wall Mounting

 

WEIGHT

750g

 

ENVIRONMENTAL

Operating Temperature       -20oC to +45oC

Operating Humidity             95% RH

Indoor Installation Only       IP 32

Screw mounting to wall etc. - multi cable knockout